The University of Illinois, and especially the ECE444 laboratory, has a long standing tradition of safety awareness. There have been no serious accidents in 35+ years of operation of the 444 lab. This handout is intended as a supplement to the information contained in the Lab Manual Supplement (ECE 444 Lab Safety, Laboratory Health and Safety: Be Aware, Be prepared, Be protected, The Sinks and Fume Hoods, Etching, Furnaces and A Word of Caution) and the safety links on the lab web page. It's your responsibility to be familiar with this material: you will be tested on it!

The first and most important tool for safety available to you is common sense. Be aware of the fact that you are working in a potentially dangerous environment where you cannot afford to be careless. Never horse around in the lab or engage in any activity that may be risky to you or other people working in the lab.

Be conscious of the safety hazards of the lab: You are working with strong chemicals, with high temperatures, with vacuum pumps and with lasers.

Safety Equipment and Procedures

Safety in the lab begins before you get into the lab. Always wear covered shoes (no sandals) and pants (shorts and skirts only mean that you have 1 layer less of clothing between you and the lab). Never wear contact lenses; they may trap chemicals against your eyes.

Before you come into the Lab make sure you are properly wearing your Tyvek® suit, cap, booties and lenses. As you come into the lab always get a pair of latex gloves (ask for vinyl if you are allergic to latex) this will provide you with the basic safety equipment, and will also protect the equipment, lab and experiments from contamination you may bring into the lab. You should wear these items at all times inside the Lab.

Be familiar with MSDSs (Material safety data sheets). These are the specifications for all the chemicals we use in the ECE444 lab. In case of an emergency medical personnel will NEED this information. The MSDS for the ECE444 are located online. Ask your TA to show you one and explain the basics of an MSDS.

The Wet Lab

The Wet Lab deserves special attention due to the potentially dangerous chemicals that are stored there.

Always wear a closed face shield inside the wet lab (You may take it off when using the microscopes, just remember to put the face shield back on when finished).

Whenever working with chemicals work under the appropriate fume hood. Most of the chemicals in the lab are volatile.

Always wear the Nitrile gloves (thick green gloves) when working in the acid or RCA hoods.

BE ESPECIALLY CAREFUL WITH THESE GLOVES:

Remember never to touch the outside of the gloves. Students are usually careful when getting in and out of the gloves, however some students tend to be careless while using the gloves. Never touch your face with the gloves, if your face / nose itches don't use your gloved hands to scratch.

Always be aware of BOTH hands. Always keep both hands above the counter. Don't let your left hand (if you are right handed for example) out of your sight, you will tend to put it by your left hip. Remember: TYVEK and LATEX will NOT PROTECT YOU FROM CHEMICALS.

If you see or feel anything wet inside the gloves let one of the TAs know, we have plenty of new gloves.

When handling chemicals for the RCA clean be careful when you get them in and out of the cabinets underneath the hoods. When you are done with the bottles and other equipment remember to rinse them before returning them to their storage place. Always open the containers underneath the hood, some of them will give off fumes as you open them.

When using the sulfuric acid on SC-2 remember your jingle "Always do as you oughta add ACID to WATER". When working with acids and water, water always goes first. When you add the sulfuric acid to the solution you will notice a sharp increase in temperature. If you pour too fast, or to a solution that is already too hot (above 60° C) you will reach (at least locally) the boiling point of H2SO4 (Sulfuric Acid). This will cause bubbling and splashing of acid outside the quartz boat. If this happens stop pouring acid immediately, turn the temperature controller off and wait for the temperature to go below 60° C before you continue to pour the acid.

The Furnaces

When working with the furnaces make sure you are wearing the appropriate gloves.

Make sure there is only one (1) person in the furnace area (marked by yellow and black tape on the floor) when someone is loading / unloading a boat.

Whenever you turn in any of the gases make sure you check the flow and pressure settings. You wan to make sure that the ball in the flow meter is floating, and that the pressure gauges read above 15 psi AFTER you turn the gas on.

Hydrogen is explosive in high concentrations or below 800°C. If any of these conditions is present on the furnaces a local high-pitched alarm will sound.

If this happens:

  1. Turn the hydrogen off
  2. Turn the alarm off by pressing the AUTO IGNITION button.
  3. Check that the furnace is at the right temperature and that oxygen is flowing
  4. Try turning the hydrogen on again, if the LOCAL alarm goes off again repeat steps 1 and 2 and contact your TA.

The Evaporators

You should always wear a face shield in the vicinity of any vacuum system using a glass bell jar. An implosion of the chamber will result with thousands of glass pieces flying in the vicinity of the machine.

Emergencies

In case of emergency, always call 911 (that is 9-911 if calling from a campus phone) and give the following information:

Your name
Location -
     Integrated Circuit Fabrication Laboratory
     Room 50Q, Basement of Everitt Lab
     1406 W. Green St.

Specific information about the emergency

Fire Alarms

In case of a fire students should evacuate (see evacuation routes) the lab as soon as possible and always in an orderly fashion.

Activate one of the regular fire alarms on your way out. Regular fire alarms require you to break a small glass to access the handle.

The special CO2 fire alarms are smaller and they don't have glass covers.

Special CO2 fire alarms:

There are two handles for these alarms. The first one is outside the Wet Lab on the door by the shower. The second one is on the north wall inside the Wet Lab, by the emergency hatch.

These alarms should only be activated in case of a fire in one of the fume hoods (either the solvent, acid, or RCA hoods in the wet lab). This alarm will flood the Wet Lab with CO2. The last person leaving the Wet lab should activate this alarm. If you are using the alarm by the emergency hatch, make sure you do it once you have at least one foot out of the hatch.

If this alarm is activated while someone is still inside the Wet Lab the CO2 will asphyxiate him/her.

Hydrogen Alarms

Hydrogen is a highly flammable and explosive gas, therefore a hydrogen alarm should be considered just as a fire alarm.

There are 2 levels of alarms reported by the Hydrogen Detection System located by the main glass doors to the lab:

Alarm Level 1

  • Prepare to evacuate the lab

If the concentration of H2 exceeds 5% of the LEL (lower explosive limit) alarm level one is activated.

This alarm level is local only (Sonalert annunciates, beacon light activated) and allows the TA a window of time to evaluate the lab for gross leaks or simple mistakes.

Alarm Level 2

  • Evacuate the building immediately

If the concentration of H2 exceeds 10% of the LEL alarm two is activated.

This is a building wide alarm which activates the lab and building fire alarm. Hydrogen levels are dangerously high and an explosion could occur.

Local Furnace H2 Alarm

  • Notify a TA

The oxidation furnaces have built-in flow meters which determine the amounts of O2 and H2 injected into the furnace. If too much H2 is injected, a local alarm at the furnace will sound.

The gas controller fails-over to a safe condition, so no evacuation is needed.

Evacuation Routes

There are 3 evacuation routes in case of an accident in the ECE444 lab. (See figure 1)

All of these routes end in front of the Everitt lab. Exit the building and wait for your TA outside the building by the bike path located at the southeast corner of Everitt Lab. It's important that TAs account for everybody, so don't take your suit off, it makes it easy for them to get a fast count of students.

Main evacuation Route 1

This route should be used in case of an emergency, if access of this route is impossible due to fire, chemicals, electrical hazard or smoke use either of the other 2 evacuation routes.

Go to the main glass door of the lab (in front of the Wet Lab's door), exit the lab, use the stairs to get to the south door of the Everitt Lab, and exit the building.

Evacuation Route 2

This route should be used when access to the Main evacuation route is not possible. You can access this evacuation route from the Test area, from the furnace area and from the Wet lab.

If you are in the Wet lab or in the Furnace area use the emergency hatches located in the north wall. Pull the red handle and exit to the service corridors.

TURN LEFT and you will end up in the gown room again. IF YOU TURN TO THE RIGHT YOU WILL FIND AN EMERGENCY EXIT DOOR THAT IS USUALLY LOCKED, YOU CAN NOT EXIT THROUGH THAT DOOR. If you are in the test area, exit to the gown room, then leave the lab through the same path you usually follow.

Exit the building and wait for your TA outside the south door of the building.

Evacuation Route 3

This route is used only for the Steppers room and the storage room. Use the door on the south wall of the Stepper room to exit to the hallway.

Exit the building and wait for your TA outside the south door of Everitt Lab


Figure 1: Evacuation Routes

Lab Safety

·Chemical Hygiene Plan

·MSDSs

·Evacuation Routes

·Fire Alarms

·Hydrogen Alarms

·Injuries

·Personal Protective Equipment

·Power Outage

·Safety Handout









In case of emergency, always call 9-911 and give the following information:

·Your name

·Location:
IC Fabrication Laboratory
Room 50Q
Basement of Everitt Lab
1406 W. Green St.

·Specific information about the emergency


Answers provided by this service may not be relevant to the materials presented in this website.

Department of Electrical and Computer Engineering
College of Engineering
University of Illinois Urbana-Champaign

Contact ece444
Copyright © 2007, 2008, 2009 The Board of Trustees at the University of Illinois. All rights reserved.

archives: ©1999 ©2000 ©2004 ©2005 ©2006